STATIC PORT
Pressure Function
Pressure Rate
Altitude Function
- ± 3 ft @ 0 ft
- ± 4 ft @ 10,000 ft
- ± 6 ft @ 20,000 ft
- ± 9 ft @ 35,000 ft
- ± 18 ft @ 50,000 ft
Climb Function
PITOT PORT
Pressure Function
Pressure Rate
Airspeed Function
- ± 1.0 knots @ 20 knots
- ± 0.3 knots @ 50 knots
- ± 0.2 knots @ 100 knots
- ± 0.1 knots @ 200 knots
- ± 0.04 knots @ 500 knots
Airspeed Rate
Mach Function
SYSTEM
Power Requirement
External Interfaces
Dimensions & weights
Environmental Specs
WiFi-enabled
RVSM & Automated operation
Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot and ± 0.1 knot. This RVSM tester’s low price makes it very affordable
Calibration period
1 year
Programmable limits
User-programmable limits for altitude, airspeed, Mach, VSI and airspeed-rate provide protection to the aircraft.
Negative-airspeed protection
An internal differential-pressure relief valve provides protection against negative airspeed.
Removable Battery (Optional)
The removable battery allows for 6 to 8 hours of continuous operation. Re-charge time is only 8 hours.
Low-temperature operation (optional)
With optional internal heaters, the unit can be operated down to -40°C
“Jog” and “Hold” features
Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.
“Ground” feature
Brings Pitot and Static outputs to ambient “ground” pressure after completing a test. Ambient pressure is constantly monitored.
“Profiles” feature
A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 15 profiles can be stored in the unit.
Leak checks
Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user.
Pressure & Vacuum source
Built-in diaphragm pumps provide the pressure and vacuum source for the unit.
Remote unit
The Remote unit is the operator interface for the tester. It features a sunlight-readable 5.8” color display, a back-lit keypad and a touch-screen (which can be disabled). All operations are performed from a single screen which displays all pertinent parameters.
Manual Vent Valves
On loss of power, the unit maintains pressure. The unit can be manually vented to “Ground” at a controlled rate using precision metering valves.
System | ||
System | Part Number | Description |
---|---|---|
131-0241 | Model 6270 Automated Pitot-Static Tester (RVSM) | |
131-0242 | Model 6270-B Automated Pitot-Static Tester w/ Battery (RVSM) | |
131-0243 | Model 6270-H Automated Pitot-Static Tester w/ Heaters (RVSM) | |
131-0244 | Model 6270-BH Automated Pitot-Static Tester w/ Battery + Heaters (RVSM) | |
131-0268 | Model 6270-BW Automated Pitot-Static Tester w/ Battery + WiFi (RVSM) | |
131-0271 | Model 6270-W Automated Pitot-Static Tester w/ WiFi (RVSM) | |
131-0275 | Model 6270-HW Automated Pitot-Static Tester w/ Heaters + WiFi (RVSM) | |
131-0302 | Model 6270-BHW Automated Pitot-Static Tester w/ Battery + Heaters + WiFi (RVSM) | |
131-0368 | Model 6270-EBHW Automated Pitot-Static Tester w/ Encoder + Battery + Heaters + WiFi (RVSM) |
Accessories | ||
Accessories
|
Part Number | Description |
---|---|---|
129-1228 | Power cable – North America (8 ft) | |
129-1328 | Power cable – UK (8 ft) | |
129-1268 | Power cable – Europe (8 ft) | |
129-1311 | Power cable – Switzerland (8 ft) | |
129-1260 | Power cable – India (8 ft) | |
129-1425 | Power cable – China (8 ft) | |
129-1440 | Power cable – Australia (8 ft) | |
118-1164 | Shipping Case for model 62xx, 6300, 6600-NG series without Hose Kits | |
118-2465 | Shipping Case for all ADTS with Hosekits, Legacy/Military ADTS, all Calibrators | |
115-0886A | Hose-kit-2 for Legacy 2-channel models | |
115-0886B | Hose-kit-2 for 2-channel models (with Tees) | |
115-1003 | Hose-kit C for 2-channel models with longer hose-lengths (30 Foot) | |
131-0264 | Universal Pitot-Static Adapter kit for GA aircraft | |
131-0236 | MOB-36: Multi-output box for 2-channels testers – 3 pitot & 6 static | |
131-0272 | MOB-44: Multi-output box for 2-channels testers – 4 pitot & 4 static | |
131-0248 | MOB-48: Multi-output box for 2-channels testers – 4 pitot & 8 static | |
115-2028 | iPad Mini Kit w/Case & 2′ remote cable | |
129-1379 | 2′ Remote cable to reduce the risk of tripping | |
129-1351 | 50′ Remote Cable |