STATIC PORT
Pressure Function
Pressure Rate
Altitude Function
- ± 2 ft @ 0 ft
- ± 6 ft @ 35,000 ft
- ± 12 ft @ 50,000 ft
- ± 50 ft @ 80,000 ft
Climb Function
PITOT PORT
Pressure Function
Pressure Rate
Airspeed Function
- ± 1.5 knots @ 20 knots
- ± 0.5 knots @ 50 knots
- ± 0.25 knots @ 100 knots
- ± 0.1 knots @ 300 knots
- ± 0.01 knots @ 1000 knots
Airspeed Rate
Mach Function
EPR Function
SYSTEM
Power Requirement
External Interfaces
Dimensions & weights
Environmental Specs
RVSM compliant
The high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant.
Calibration period
1 year
Pressure & Vacuum system
The unit includes dual vacuum pumps and a pressure pump for higher reliability. The pressure system includes a membrane dryer and filter to provide clean dry air for the entire system. No external pumps are required. Internal pumps have a minimum life of 5000 operating hours.
Automated operation
Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot, ± 0.1 knot or ±0.001 inHg.
Programmable limits
User-programmable limits for altitude, airspeed, Mach and VSI provide protection to the aircraft.
“Jog” and “Hold” features
Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.
“Ground” feature
Brings Pitot and Static outputs to ambient “ground” pressure after completing a test.
“Profiles” feature
A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 20 profiles can be stored in the unit.
Leak checks
Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user.
Local display and keypad
The local display and keypad are the operator interface for the tester. All valid parameters, including altitude, climb and airspeed, are clearly displayed simultaneously on a single screen on the local display.
APPLICATIONS
Since the pumps are included, this is the Ideal tester for rack-mount ATE systems.
Ideal tester for use in an instrument-shop for testing and calibrating ADC’s, altimeters, airspeed indicators, VSI’s, cabin pressure controllers, FDR’s and other air-data instruments.
System | ||
System | Part Number | Description |
---|---|---|
131-0327 | Model 6580 High Accuracy Air Data Bench Test Set, Rack mount with built-in pressure source and vacuum | |
131-0211 | Model 6580 Air Data Bench Test Set, Rack mount with built-in pressure source and vacuum |