Model 6600Automated Pitot Static Tester with 3 Outputs

The 6600 Automated Tester is ideal for use on aircraft with SmartProbeā„¢ capable of measuring AOA using Air Data. The tester has one Static output (Ps1), one Pitot output (Pt) and a third output (Ps2) which can be used to simulate either AOA or AOS. Using the small and light-weight Remote unit a user can operate the tester from the cockpit and test the entire pitot and static system of the aircraft. The tester includes built-in vacuum and pressure pumps and emergency manual bleed-down valves. The high accuracy of this unit meets all RVSM requirements. Calibration is required only once a year.

Last time buy for this product is June 30, 2021.
For new requirements, we recommend Model 6600-NG

Static Output

Pressure function

Range:

0.1 to 42 inHg

Resolution:

0.001 inHg

Accuracy:

Ā±0.002 inHg

Units:

inHg, mbar

Altitude function

Range:

-4000 ft. to 60,000 ft.

Resolution:

1 foot

Accuracy:

Ā± 2 ft. @ 0 ft.
Ā± 6 ft. @ 35,000 ft.
Ā± 12 ft. @ 50,000 ft.

Units:

Feet, Meters

Climb function

Range:

0 ft/min to Ā±25,000 ft/min

Resolution:

1 ft/min

Accuracy:

Ā±1% of rate of climb

Units:

Feet/min, Meters/sec

Pitot Output

Pressure Function

Range:

0.1 to 60 inHg

Resolution:

0.001 inHg

Accuracy:

Ā±0.003 inHg

Pt Units:

inHg, mbar, EPR

Qc Units:

inHg, mbar

Airspeed Function

Range:

0 to 650 knots

Resolution:

0.1 knots

Accuracy:

Ā± 0.5 knots @ 50 knots
Ā± 0.25 knots @ 100 knots
Ā± 0.05 knots @ 650 knots

Units:

knots, Mach, km/hr, mph

Rate of change:

0 to 500 knots/min

Mach Function

Range:

0.0 to 3.0 Mach

Resolution:

0.001 Mach

Accuracy:

Ā±0.001 above 0.2 Mach

Differential Output (referenced to Static)

Secondary Static or Pitot Output

Range:

-30.0 to +30.0 inHg

Resolution:

0.001 inHg

Accuracy:

Ā±0.002 inHg

Units:

inHg, mbar, Dfin, Dfmb, feet, mtrs, knots, kmph

Power Requirement

90-260 VAC, 47-440 Hz ; 200 VA

External Interfaces

RS232 ; IEEE-488 & Encoder optional

Dimensions & weights

Main unit:

22ā€ x 14ā€ x 9ā€ / 40 lbs

Remote unit:

7ā€ x 8ā€ x 2ā€ / 1 lb.

Environmental Specs

Operating temp.

0 to 50Ā°C

Storage temp.:

-25Ā°C to 75Ā°C

Humidity:

5 to 100%

Test Set Type

Air Data Ramp

Aircraft Type

Business Jet, Commercial

RVSM Capable

Yes

Max Aircraft Altitude

50,000 ft, 60,000 ft

Max Aircraft Airspeed

500 knots, 600 knots, 650 knots

Scroll to Top